Tipo de bloqueo
Fixing flange with thread 4-40 UNC
Technical characteristics
Distancia entre contactos (lado de terminación)
2.54 mm
Flange height
7.3 mm
Corriente nominal
5 A
Rated current (power)
20 A
Resistencia de aislamiento
>105 Ω
Contact resistance, signal area
≤ 10 mΩ
Contact resistance, power area
≤ 1 mΩ
Tightening torque
≤0.6 Nm Female screw lock
Limiting temperature
-55 ... +125 °C
Performance level
NM 30 (S4)
1
Ciclos de conexión
≥ 500
Test voltage Ur.m.s.
1 kV
Isolation group
IIIa (175 ≤ CTI < 400)
Grosor de placa de circuitos impresos
1.6 mm
Hot plugging
No
Material properties
Material (insert)
Thermoplastic resin, glass-fibre filled (PBT)
Shell: steel, tin plated
Colour (insert)
Green
Material (contacts)
Copper alloy
Surface (contacts)
Gold plated Mating side
Sn over Ni Termination side
Layer thickness
≥ 0.76 µm
Layer thickness
≥ 30 µinch
Material flammability class acc. to UL 94
V-0
RoHS
compliant with exemption
RoHS exemptions
6(a) / 6(a)-I: Lead as an alloying element in steel for machining purposes and in galvanised steel containing up to 0,35 % lead by weight / Lead as an alloying element in steel for machining purposes containing up to 0,35 % lead by weight and in batch hot dip galvanised steel components containing up to 0,2 % lead by weight
6(c): Copper alloy containing up to 4 % lead by weight
ELV status
compliant with exemption
China RoHS
50
REACH Annex XVII substances
Not contained
REACH ANNEX XIV substances
Not contained
REACH SVHC substances
Yes
REACH SVHC substances
Lead
ECHA SCIP number
ecef7555-f643-4ceb-a337-fc54762297f1
California Proposition 65 substances
Yes
California Proposition 65 substances
Lead
Nickel
Fire protection on railway vehicles
EN 45545-2 (2020-08) + A1 (2023-10)