Not be coupled or decoupled under electrical load.
Assembly and installation must be carried out by a qualified electrician.
Protection against electric shock: Protection against indirect contact (fault protection) shall be ensured by suitable measures taken by the user during installation. E. g. by restricted access area (area accessible only to electrically skilled persons and electrically instructed persons).
Technical characteristics
Rated current
110 A
Rated voltage
1.500 V
Rated impulse voltage
8 kV
Pollution degree
2
Insulation resistance
>108 Ω
Limiting temperature
-40 ... +120 °C no desplazado
-40 ... +90 °C movido
Number of relockings
≥ 500
Degree of protection acc. to IEC 60529
IP40 mated condition
IP20 unmated condition (1500 V DC; 1000 V AC)
Cable diameter
8,4 mm
Material properties
Material (cable)
Copolímero de poliolefina
Colour (cable)
Negro
RoHS
conforme
ELV status
conforme
China RoHS
e
REACH Annex XVII substances
No incluido
REACH ANNEX XIV substances
No incluido
REACH SVHC substances
No incluido
California Proposition 65 substances
No incluido
Specifications and approvals
Specifications
EN 50264-3-1
EN 60811-403 Resistencia al ozono
EN 60811-504 Alta resistencia a las bajas temperaturas
EN 60811-404 Resistencia al aceite
EN 60811-404 Alta resistencia al combustible
EN 60811-404 Resistencia al ácido
EN 60811-404 Resistencia alcalina
DIN 51900 Baja carga de fuego
ISO 4589-2 Índice de oxígeno límite (LOI)
EN 50618 Resistente a rayos UV
UN/ECE-R 118 protección contra incendios para material rodante