2 contacts with relay function (last mate - first break)
Enables other power contacts to be switched off via a relay and thus offers greater safety in the event of a fault (when used as intended, the connector must not be plugged in or disconnected under voltage / load)
Version
Termination method
Crimp termination
Gender
Male
Number of contacts
3
Details
Please order crimp contacts separately.
Technical characteristics
Conductor cross-section
0.14 ... 4 mm²
Wire outer diameter
≤4.8 mm
Rated current
16 A
Rated voltage
500 V
Rated impulse voltage
6 kV
Pollution degree
3
Insulation resistance
>1010 Ω
Limiting temperature
-40 ... +125 °C
Mating cycles
≥ 500
Lock-in range
± 4 mm
Material properties
Material (insert)
Polycarbonate (PC)
Colour (insert)
RAL 7032 (pebble grey)
Material flammability class acc. to UL 94
V-0
RoHS
compliant
ELV status
compliant
China RoHS
e
REACH Annex XVII substances
Not contained
REACH ANNEX XIV substances
Not contained
REACH SVHC substances
Not contained
California Proposition 65 substances
Not contained
Fire protection on railway vehicles
EN 45545-2 (2020-08)
Requirement set with Hazard Levels
R22 (HL 1-3)
R23 (HL 1-3)
Specifications and approvals
Specifications
IEC 60664-1
IEC 61984
Commercial data
Packaging size
2
Net weight
0.1 kg
Country of origin
China
European customs tariff number
85389099
GTIN
5713140184695
ETIM
EC000438
eCl@ss
27440217 Module for industrial connectors (power/signals)