A Han® 1A configuration that only consists of inserts (with or without strain relief, 09 10 000 5300) is an unenclosed connector. In this case protection against electric shock must be provided by the installation methods of the user.
Only for use with single wires according to CSA approval.
Technical characteristics
Limiting temperature
-30 ... +90 °C
Note on the limiting temperature
For use as a connector according to IEC 61984.
Number of relockings
< 10
Degree of protection acc. to IEC 60529
IP20
Material properties
Material (hood/housing)
Polyamide (PA)
Colour (hood/housing)
RAL 9005 (jet black)
Material (seal)
TPE
Colour (seal)
Yellow
Material flammability class acc. to UL 94
V-0
RoHS
compliant
ELV status
compliant
China RoHS
e
REACH Annex XVII substances
Not contained
REACH ANNEX XIV substances
Not contained
REACH SVHC substances
Not contained
Fire protection on railway vehicles
EN 45545-2 (2020-08)
Requirement set with Hazard Levels
R22 (HL 1-3)
R23 (HL 1-3)
Specifications and approvals
Specifications
EN 45545-2 Fire protection on railway vehicles
IEC 61373 Category 1 Class B
UL / CSA
UL 1977 ECBT2.E235076
CSA-C22.2 No. 182.3 ECBT8.E235076
Please contact your local HARTING subsidiary for further information.